Mfg Part Number: WE-4168 | Alternate P/N: WE4168 | NSN : 5950-01-330-7680 |
NIIN : 013307680 | CAGE Code : 13973 | Manufacturer: Litton Systems Inc |
Item Name : Reactor Transformer | FSC : 5950 Coils and Transformers |
Automatize Buying is committed to providing you with only the highest-quality NSN parts and components such as 5950-01-330-7680 with part number WE-4168. We work closely alongside our suppliers and manufacturers like Litton Systems Inc, selecting only those that meet or exceed your needs so we can offer a hassle-free experience when it comes time for installation! You can trust us to provide you with the best pricing and service. We always give our customers more than they could hope for, all at an affordable price. Why wait? Start getting the competitive quotes you need with an instant RFQ.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-330-7680 Item Description: Reactor Transformer | 5950 | 013307680 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
We-4168 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.790 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.810 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.790 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.810 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 1.100 INCHES MAXIMUM |
ACYV | INDUCTANCE RATING | 2.00 MILLIHENRIES NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
ACYV | INDUCTANCE RATING | 34.00 MICROHENRIES NOMINAL SINGLE COMPONENT SINGLE WINDING |
ADAU | BODY HEIGHT | 1.220 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AKPV | MOUNTING FACILITY QUANTITY | 2 SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE WINDING |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 180.0 MILLIAMPERES DC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 7.0 AMPERES DC MAXIMUM SINGLE COMPONENT SINGLE WINDING |
CWJS | WINDING OPERATING VOLTAGE | 1.20 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 13973-865530 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
ADAQ | BODY LENGTH | 1.100 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 125.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 12.02 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE WINDING |
![]() |